Home Transformer Siemens 1LPC Distribution Dry Type Transformer

Siemens 1LPC Distribution Dry Type Transformer

share
Siemens 1LPC Distribution Dry Type Transformer
Manufacturer: Siemens

Economical Space Saving Package Siemens Sentron Power Center is a pre-wired combination of a primary breaker disconnect, dry type shielded transformer, secondary breaker disconnect and a secondary power panel all in one convenient package.

UL-3R Enclosures

All Sentron Power Center enclosures are UL-3R listed for indoor and outdoor use.

Transformer Assembly

Siemens totally encapsulated distribution transformers are designed for general purpose indoor/outdoor operation.

Sentron Power Centers can be installed in a wide variety of atmospheric and environmental conditions. A 180°C, UL recognized insulation system is used with a 115°C temperature rise.

Sentron Power Center units are electrostatically shielded to provide transient voltage protection at no extra cost. All units have 2-5% FCBN taps.

Panel Assembly

The power panel assembly will accommodate one-inch, 1, 2 or 3-pole, common trip, duplex secondary branch circuit breakers, Type Q and QT as well as ground fault circuit breakers. Per UL and NEC requirements, the Sentron Power Center assembly comes fully equipped with primary and secondary main circuit breakers. Branch circuit breakers can be obtained from our local distributor once you have established your branch circuit requirements. All Sentron Power Centers are UL listed for service entrance.

More+
Features Model
  • Primary breaker has lineside lug for customer connection.
  • 18,000 Amps RMS Symmetrical Interrupting Capacity.
  • Sentron Power Centers are NEMA 3R for outdoor application and may be ordered with “SS” suffix for 304 stainless steel enclosure. For 316 stainless steel add suffix SS316.
  • Secondary branch breakers are not included and must be ordered separately.
  • Primary and secondary main breakers are included and are factory installed.
  • ED frame breakers furnished are rated 18000 AIC and are sufficient for fault current of transformer. If higher AIC rating is required by spec, the ED can be changed in the field to HED 4 (42000 AIC).
  • Copper windings are standard on 1LPC005 and 3LPC009.
  • Add CU to other partnumber to get copper windings.
  • If SS316 or SS and CU are all specified, add to end of base part number in sequence SSCU or SS316CU.
  • CU and CUB interiors have tin plated copper bus.
  • 1-Phase 5 thru 10kVA have aluminum bus. CUB refers to OEM interior verses CU un-assembled interior.
Mfr. Part No. Description
1LPC005 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 8
1LPC007 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 8
1LPC010 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 8
1LPC015 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 12
1LPC025 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 20
3LPC009 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 12
3LPC015 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 12
3LPC022 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 18
3LPC030 Maximum Secondary Circuits, 1" Wide, 120V (1-Pole), 24